Valley and flashing metal shall be a minimum uncoated thickness of 0.0179-inch (0.5 mm) zinc coated G90. Drip edges shall extend not less than. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. R905.2.1 Sheathing requirements. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. (914 mm). Self-adhering polymer-modified bitumen. The installation of thermoset single-ply roofing shall comply with the provisions of this section. 3. 1. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall be fastened to solidly sheathed decks. CHAPTER 8 ROOF-CEILING CONSTRUCTION. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. R905.2Asphalt shingles. (R803.1) Spaced lumber sheathing is not allowed in Seismic Design Category D 2. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch- diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Mineral-surfaced roll roofing shall not be applied on roof. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). The installation of wood shingles shall comply with the provisions of this section. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. endstream endobj 202 0 obj <. 2018, 2021 IECC: Mass walls shall be in accordance with Section R402.2.5 (N1102.2.5 in 2018 IRC). R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panels and Modules, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings. The second R-value applies when more than half of the insulation is on the interior of the mass wall. the 2018 International Residential Code (IRC) simplified wall bracing requirements. 12 oz/sq ft for preformed metal shingle systems. Allowable spans for lumber sheathing shall conform to IRC Table R803.1. Participants will be able to use this document to identify changes between the 2015 and 2018 IRC allowing them to apply theses code requirements to design, plan submittals and/or inspection. Roofing materials must be installed in accordance with Chapter 9 of the 2020 Minnesota Residential Code and the manufacturer's installation Rooftop-mounted photovoltaic systems shall be installed in accordance with the manufacturer's instructions. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. (R803.1) Hold-Downs and Hardware For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. IRC Section 301.3 Story Height: The ability is restored to construct a story of a dwelling using 12-foot high bearing walls if the wall studs are engineered for gravity loads, wall bracing amounts are increased, and a roof or celling diaphragm provides support to the studs. Wood shakes shall comply with the requirements of Table R905.8.5. Where the roof, Where required, ice barriers shall comply with. Minimum headlap for slate shingles shall be in accordance with Table R905.6.5. Slate shingles shall comply with ASTM C406. Where siding is provided on the vertical sidewall, the vertical leg of the flashing shall be continuous under the siding. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. Water soaked or deteriorating decking must be replaced. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D3909 or ASTM D6380 Class M, shall be permitted. A liquid-applied protective coating that complies with Table 905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Asphalt shingles shall comply with ASTM D3462. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Slate shingles shall comply with ASTM C406. The 2018 IRC specifies the ratios based on climate zone. Foam plastic materials and installation shall comply with. Table 1 shows an insulation ratio - the R-value on the top of the roof sheathing compared to the total R-value. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. The installation of wood shingles shall comply with the provisions of this section. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Mineral-surfaced roll roofing shall not be applied on roof. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, In areas where the average daily temperature in January is 25F (-4C) Valley flashing shall be not less than 15 inches (381 mm) wide. 3. Install flashing at roof penetrations and wall intersections. 12 oz/sq ft for preformed metal shingle systems. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum 3 / 8 -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than 3 / 4 inch (19.1 mm) into the roof sheathing. Interlayment shall comply with ASTM D226, Type I. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Asphalt shingles shall be fastened to solidly sheathed decks. Plywood is a wood structural panel covered in R803.2.2 which points you to R503.2.1.1 There is a lot of cross over between chapters 5, 6, and 8, so don't just go with the chapter titles of floor, wall, roof. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. . Materials and methods of application used for re-covering or replacing an existing, The structural roof components shall be capable of supporting the, Roof replacement shall include the removal of existing layers of, Flashings shall be reconstructed in accordance with. Slate shingles shall be secured to the roof with two fasteners per slate. Flashing and counterflashing shall be made with sheet metal. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Self-adhering polymer-modified bitumen. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D 3909 or ASTM D 6380 Class M, shall be permitted. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Please see IRC Sec- In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. are not required for roofs sheathed with lumber having a nominal width of less than 3 feet Asphalt shingles shall be used only on roof. Foam plastic materials and installation shall comply with Section 316. roof sheathing, skylights, change of roof pitch, addition or relocation of mechanical units, or installation of heavier materials than were previously installed. Where the existing roof covering is wood shake, slate, clay, cement or asbestos-cement tile. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s. 2018 International Residential Code (IRC) COPYRIGHT PREFACE EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE arrow_right CHAPTER 1 SCOPE AND ADMINISTRATION arrow_right CHAPTER 2 DEFINITIONS arrow_right CHAPTER 3 BUILDING PLANNING arrow_right CHAPTER 4 FOUNDATIONS arrow_right CHAPTER 5 FLOORS arrow_right CHAPTER 6 WALL CONSTRUCTION arrow_right Spaced lumber decking CoL Refer to the manufacturer's technical bulletin regarding requirements for existing deck boards. The installation of wood shingles shall comply with the provisions of this section. Roof valley flashing shall be not less than No. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Self-adhering polymer modified bitumen. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Section R804 Cold-Formed Steel Roof Framing Section R806 Roof Ventilation Section R807 Attic Access Chapter 9 Roof Assemblies R905.2 Asphalt shingles. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Where the existing roof or roof covering is water-soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Asphalt shingles shall be fastened to solidly sheathed decks. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Interlayment shall comply with ASTM D226, Type I. A base sheet that complies with the requirements of. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with Section 703.8.2.2. For the most common roof sheathing in our area, which is 1/2" nominal (7/16" actual) sheathing over trusses or rafters at 24" on center . For roofs that provide positive drainage, re-covering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, The application of a new protective coating over an existing spray polyurethane foam roofing system shall be permitted without tear-off of existing, Where the existing roof has two or more applications of any type of. The installation of mineral-surfaced roll roofing shall comply with this section. Asphalt shingles shall be tested in accordance with ASTM D7158. Asphalt shingles shall comply with ASTM D3462. It guides the participant through an in-depth review and analysis of the bracing requirements for wood-framed residential structures. Drip edges shall extend not less than. A new Footnote j Flashing against a vertical front wall, as well as soil. Modified bitumen roofing shall comply with the standards in Table R905.11.2. Slate shingles shall be secured to the roof with two fasteners per slate. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum, Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's, Where required, ice barriers shall comply with, Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Galvanized fasteners shall be used for steel roofs. Class A, B or C roofing shall be installed in, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing. Fifteen-inch (381 mm) or 18-inch (457 mm) wood shakes shall be permitted to be used for the final course at the. Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. The installation of asphalt shingles shall comply with the provisions of this section. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Slate shingles shall be fastened to solidly sheathed roofs. Wood shingles shall be laid with a side lap not less than 1, NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES, Roof flashing shall be not less than No. Valley linings shall be installed in accordance with the manufacturer's instructions before applying shingles. Valley linings of the following types shall be permitted: For SI: 1 inch = 25.4 mm, 1 pound = 0.454 kg. Foam plastic materials and installation shall comply with. Flashing and counterflashing shall be made with sheet metal. (R803.1) Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of sections R905.7 and R905.8. Flashing for asphalt shingles shall comply with this section. SECTION R804 COLD-FORMED STEEL ROOF FRAMING. Asphalt shingles shall be tested in accordance with ASTM D7158. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. Asphalt shingle packaging shall bear a. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. Base and cap flashing shall be installed in accordance with manufacturer's instructions. endstream endobj startxref Part III Building Planning and Construction, R907 Rooftop-Mounted Photovoltaic Panel Systems, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections, Flashings shall be installed in a manner that prevents moisture from entering the wall and roof through joints in copings, through moisture permeable materials and at intersections with parapet, Flashings shall be installed at wall and roof intersections, wherever there is a change in roof, A cricket or saddle shall be installed on the ridge side of any, The requirements set forth in this section shall apply to the application of, ASTM D6380 Class M mineral-surfaced roll roofing.
Nwoye And Ikemefuna Relationship, Cosas De Colombia Que No Hay En Estados Unidos, Slow Rising Hcg Levels And Healthy Pregnancy, Sidney Hinton Net Worth, Britannia Building Society Bereavement, Articles OTHER